USAGE AREA

MEANWELL ODLV Series Constant Voltage Power Supply

$ 39.94 $ 46.00

Many In Stock

Ballast /Drivers

ODLV-45-24

S7

Add to wishlist

Features:

  • Constant Voltage PWM style output with frequency 1KHz
  • Plastic housing with class ll design
  • Built-in active PFC function
  • No load power consumption<0.5W(Blank-Type}
  • lP67 rating for indoor or outdoor installations
  • Function options: 2 in 1 dimming (dim-to-off}; Auxiliary DC output

Applications:

  • LED strip lighting
  • lndoor LED lighting
  • LED decorative lighting
  • LED architecture lighting

Model Encoding:

ODLV-45A-12:

ODLV----->Series name

45---->Rated wattage 

A----->Function options

12---->Rated output voltage(12/24/36/48/60V} 

Type

Function

Blank

2 in 1 dimming (0~10VDC and 10V PWM}

A

2 in 1 dimming and Auxiliary DC output

 

MODEL

ODLV-45 -12

ODLV-45 -24

ODLV-45 -36

ODLV-45 -48

ODLV-45 -60

DC VOLTAGE

12V

24V

36V

48V

60V

 

RATED CURRENT

3.0A

1.88A

1.25A

0.94A

0.75A

 

RATED POWER

36W

45.12W

45W

45.12W

45W

 

DIMMING RANGE

0~100%

 

VOLTAGE TOLERANCE

±10%

 

PWM FREQUENCY (Typ.)

1KHz(±20%)

 

SETUP TIME Note.3

500ms / 230VAC        1200ms/115VAC

 

AUXILIARY DC OUTPUT Note.4

Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only

 

VOLTAGE RANGE Note.2

90 ~ 295VAC         127 ~ 417VDC

(Please refer to "STATIC CHARACTERISTIC" section)

 

FREQUENCY RANGE

47 ~ 63Hz

 

 

POWER FACTOR (Typ.)

PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

 

 

TOTAL HARMONIC DISTORTION

THD< 20%(@load≧60%/115VAC,230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION” section)

 

EFFICIENCY (Typ.)

84%

86%

88%

88%

90%

 

AC CURRENT (Typ.)

0.6A / 115VAC      0.4A / 230VAC         0.3A / 277VAC

 

INRUSH CURRENT(Typ.)

COLD START 30A(twidth=150μs measured at 50% Ipeak) at 230VAC; Per NEMA 410

 

MAX. No. of PSUs on 16A CIRCUIT BREAKER

 

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

 

LEAKAGE CURRENT

<0.75mA / 277VAC

 

NO LOAD POWER CONSUMPTION

<0.5W for Blank-Type, <1.2W for A-Type

 

SHORT CIRCUIT

Shut down O/P voltage, re-power on to recovery

 

 

OVER CURRENT

105 ~ 115%

 

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

WORKING TEMP.

Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)

 

MAX. CASE TEMP.

Tcase=+85℃

 

WORKING HUMIDITY

20 ~ 90% RH non-condensing

 

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

 

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

 

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

SAFETY STANDARDS

UL8750(type”HL”),CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14; BIS IS15885( for ODLV-45-12,24,48 only), EAC TP TC 004,IP67 approved

 

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

 

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

 

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020

 

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV),EAC TP TC 020

 

MTBF

388.02K hrs min.      MIL-HDBK-217F (25℃)

 

DIMENSION

111*77*28.5mm (L*W*H)

 

PACKING

0.42Kg;24pcs/11Kg/ 0.72CUFT

 

MODEL

ODLV-65 -12

ODLV-65 -24

ODLV-65 -36

ODLV-65 -48

ODLV-65 -60

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

24V

36V

48V

60V

RATED CURRENT

4.2A

2.4A

1.8A

1.35A

1.08A

RATED POWER

50.4W

57.6W

64.8W

64.8W

64.8W

DIMMING RANGE

0~100%

VOLTAGE TOLERANCE

±10%

PWM FREQUENCY (Typ.)

1KHz(±20%)

SETUP TIME Note.3

500ms / 230VAC

AUXILIARY DC OUTPUT Note.4

Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only

 

 

 

 

 

 

 

INPUT

VOLTAGE RANGE Note.2

180 ~ 295VAC         254 ~ 417VDC

(Please refer to "STATIC CHARACTERISTIC" section)

FREQUENCY RANGE

47 ~ 63Hz

 

POWER FACTOR (Typ.)

PF>0.95/230VAC, PF>0.9/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

 

TOTAL HARMONIC DISTORTION

THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION” section)

EFFICIENCY (Typ.)

85%

87%

88%

89%

90%

AC CURRENT (Typ.)

0.4A/230VAC         0.3A/277VAC

INRUSH CURRENT(Typ.)

COLD START 30A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. No. of PSUs on 16A CIRCUIT BREAKER

 

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

NO LOAD POWER CONSUMPTION

<0.5W for Blank-Type, <1.2W for A-Type

 

 

PROTECTION

SHORT CIRCUIT

Shut down O/P voltage, re-power on to recovery

 

OVER CURRENT

105 ~ 115%

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

 

 

 

ENVIRONMENT

WORKING TEMP.

Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)

MAX. CASE TEMP.

Tcase=+85℃

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 45℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

 

SAFETY & EMC

 

SAFETY STANDARDS

UL8750(type”HL”),CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14; BIS IS15885( for ODLV-65-12,24,48 only), EAC TP TC 004,IP67 approved

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV),EAC TP TC 020

 

 

OTHERS

MTBF

398.7K hrs min.      MIL-HDBK-217F (25℃)

DIMENSION

121*77*28.5mm (L*W*H)

PACKING

0.43Kg;24pcs/11.3Kg/ 0.74CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2. De-rating may be needed under low input voltages. Please refer to “STATlC CHARACTERlSTlC” sections for details.

3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.

4. Aux. 12V will be damaged with short circuit; lt will not be available with dimming off or output no load condition.

5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

7. For any application note and lP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Recently Viewed Items


People who bought this product, also bought