MEANWELL Constant Current APC Power Supply
Many In Stock
Ballast /Drivers
APC-16-350
S7G1
- Constant current mode design
- Universal AC input / Full range
- Protections:Short circuit / Over voltage
- Fully isolated plastic case
- Small and compact size
- Cooling by free air convection
- Class Ⅱ power unit, no FG
- Class 2 power unit
- Pass LPS
- IP42 design
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices}
- 100% full load burn-in test
- Low cost / High reliability
Specification:
MODEL |
APC-16-350 |
APC-16-700 |
|
OUTPUT |
RATED CURRENT |
350mA |
700mA |
DC VOLTAGE RANGE |
12~48V |
9~24V |
|
RATED POWER |
16.8W |
16.8W |
|
RIPPLE & NOISE (max.) Note.2 |
300mVp-p |
250mVp-p |
|
VOLTAGE TOLERANCE Note.3 |
±5.0% |
||
CURRENT ACCURACY |
±8.0% |
||
LINE REGULATION |
±1.0% |
||
LOAD REGULATION |
±3.0% |
||
SETUP, RISE TIME |
3000ms, 200ms / 230VAC 3000ms, 200ms / 115VAC at full load |
||
HOLD UP TIME (Typ.) |
20ms/230VAC 12ms/115VAC at full load |
||
INPUT |
VOLTAGE RANGE Note.4 |
90 ~ 264VAC 127 ~ 370VDC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
EFFICIENCY(Typ.) |
84% |
83% |
|
AC CURRENT |
0.3A/230VAC;0.5A/115VAC |
||
INRUSH CURRENT(Typ.) |
COLD START 45A(twidth=210μs measured at 50% Ipeak) at 230VAC |
||
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
13 units (circuit breaker of type B) / 23 units (circuit breaker of type C) at 230VAC |
||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||
PROTECTION |
OVER VOLTAGE |
50.4~ 60V |
27.6~ 33.5V |
Protection type : Shut off o/p voltage, clamping by zener diode |
|||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ 70℃(Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-40 ~ +80℃, 10 ~ 95% RH |
||
TEMP. COEFFICIENT |
±0.2%/℃ (0 ~ 50℃) |
||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS Note.7 |
UL8750, CSA C22.2 No.250.0-08,BIS IS15885, EAC TP TC 004 approved, Design refer to EN60950-1 |
|
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
||
EMC EMISSION |
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020 |
||
EMC IMMUNITY |
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020 |
||
OTHERS |
MTBF |
1145.7K hrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
77*40*29(L*W*H) |
||
PACKING |
0.1Kg; 120pcs/14Kg/1.06CUFT |
MODEL |
APC-25-350 |
APC-25-500 |
APC-25-700 |
APC-25-1050 |
|
OUTPUT |
RATED CURRENT |
350mA |
500mA |
700mA |
1050mA |
DC VOLTAGE RANGE |
25~70V |
15~50V |
11~36V |
9~24V |
|
RATED POWER |
24.5W |
25.2W |
25.2W |
25.2W |
|
RIPPLE & NOISE (max.) Note.2 |
300mVp-p |
300mVp-p |
300mVp-p |
300mVp-p |
|
VOLTAGE TOLERANCE Note.3 |
±5.0% |
||||
CURRENT ACCURACY |
±8.0% |
||||
LINE REGULATION |
±1.0% |
||||
LOAD REGULATION |
±3.0% |
||||
SETUP, RISE TIME |
1500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load |
||||
HOLD UP TIME (Typ.) |
20ms/230VAC 12ms/115VAC at full load |
||||
INPUT |
VOLTAGE RANGE Note.4 |
90 ~ 264VAC 127 ~ 370VDC |
|||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
EFFICIENCY(Typ.) |
83% |
83% |
83% |
83% |
|
AC CURRENT |
0.4A/230VAC;0.8A/115VAC |
||||
INRUSH CURRENT(Typ.) |
COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC |
||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC |
||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||
PROTECTION |
OVER VOLTAGE |
76 ~ 94V |
55 ~ 68V |
41 ~ 49V |
27 ~ 35V |
Protection type : Shut down o/p voltage, re-power on to recover |
|||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ 70℃(Refer to "Derating Curve") |
|||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-40 ~ +80℃, 10 ~ 95% RH |
||||
TEMP. COEFFICIENT |
±0.2%/℃ (0 ~ 50℃) |
||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS |
UL8750 (except for APC-25-350), CSA-C22.2 No. 250.0-13 (only for APC-25-700&1050), BIS IS15885, EAC TP TC 004, IP42 approved; design refer to EN60950-1 |
|||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
||||
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
||||
EMC EMISSION |
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020 |
||||
EMC IMMUNITY |
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020 |
||||
OTHERS |
MTBF |
518.9K hrs min. MIL-HDBK-217F (25℃) |
|||
DIMENSION |
84*57*29.5(L*W*H) |
||||
PACKING |
0.13Kg; 72pcs/10.4Kg/0.92CUFT |
MODEL |
APC-35-350 |
APC-35-500 |
APC-35-700 |
APC-35-1050 |
|
OUTPUT |
RATED CURRENT |
350mA |
500mA |
700mA |
1050mA |
DC VOLTAGE RANGE |
28~100V |
25~70V |
15~50V |
11~33V |
|
RATED POWER |
35W |
35W |
35W |
34.7W |
|
RIPPLE & NOISE (max.) Note.2 |
350mVp-p |
350mVp-p |
350mVp-p |
350mVp-p |
|
VOLTAGE TOLERANCE Note.3 |
±5.0% |
||||
CURRENT ACCURACY |
±8.0% |
||||
LINE REGULATION |
±1.0% |
||||
LOAD REGULATION |
±3.0% |
||||
SETUP, RISE TIME |
1500ms, 40ms / 230VAC 1500ms, 40ms / 115VAC at full load |
||||
HOLD UP TIME (Typ.) |
20ms/230VAC 12ms/115VAC at full load |
||||
INPUT |
VOLTAGE RANGE Note.4 |
90 ~ 264VAC 127 ~ 370VDC |
|||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
EFFICIENCY(Typ.) |
84% |
84% |
84% |
84% |
|
AC CURRENT |
0.5A/230VAC;0.75A/115VAC |
||||
INRUSH CURRENT(Typ.) |
COLD START 45A(twidth=490μs measured at 50% Ipeak) at 230VAC |
||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC |
||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||
PROTECTION |
OVER VOLTAGE |
110 ~ 130V |
77 ~ 91V |
55 ~ 65V |
36 ~ 43V |
Protection type : Shut down o/p voltage, re-power on to recover |
|||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ 70℃(Refer to "Derating Curve") |
|||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-40 ~ +80℃, 10 ~ 95% RH |
||||
TEMP. COEFFICIENT |
±0.2%/℃ (0 ~ 50℃) |
||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS |
UL8750 (only for APC-35-700&1050), CSA-C22.2 No. 250.0-13 (only for APC-35-1050), BIS IS15885, EAC TP TC 004, IP42 approved; design refer to EN60950-1 |
|||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
||||
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
||||
EMC EMISSION |
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020 |
||||
EMC IMMUNITY |
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020 |
||||
OTHERS |
MTBF |
518.9K hrs min. MIL-HDBK-217F (25℃) |
|||
DIMENSION |
84*57*29.5(L*W*H) |
||||
PACKING |
0.18Kg; 72pcs/14Kg/0.92CUFT |
||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristic for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. 8. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf |