Specification:

MODEL

APC-16-350

APC-16-700

 

 

 

 

 

 

OUTPUT

RATED CURRENT

350mA

700mA

DC VOLTAGE RANGE

12~48V

9~24V

RATED POWER

16.8W

16.8W

RIPPLE & NOISE (max.) Note.2

300mVp-p

250mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

CURRENT ACCURACY

±8.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±3.0%

SETUP, RISE TIME

3000ms, 200ms / 230VAC          3000ms, 200ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC      12ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE           Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY(Typ.)

84%

83%

AC CURRENT

0.3A/230VAC;0.5A/115VAC

INRUSH CURRENT(Typ.)

COLD START 45A(twidth=210μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

13 units (circuit breaker of type B) / 23 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

 

OVER VOLTAGE

50.4~ 60V

27.6~ 33.5V

Protection type : Shut off o/p voltage, clamping by zener diode

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ 70℃(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.2%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

SAFETY & EMC

(Note 5)

SAFETY STANDARDS Note.7

UL8750, CSA C22.2 No.250.0-08,BIS IS15885, EAC TP TC 004 approved, Design refer to EN60950-1

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020

 

OTHERS

MTBF

1145.7K hrs min.      MIL-HDBK-217F (25℃)

DIMENSION

77*40*29(L*W*H)

PACKING

0.1Kg; 120pcs/14Kg/1.06CUFT

MODEL

APC-25-350

APC-25-500

APC-25-700

APC-25-1050

 

 

 

 

 

 

OUTPUT

RATED CURRENT

350mA

500mA

700mA

1050mA

DC VOLTAGE RANGE

25~70V

15~50V

11~36V

9~24V

RATED POWER

24.5W

25.2W

25.2W

25.2W

RIPPLE & NOISE (max.) Note.2

300mVp-p

300mVp-p

300mVp-p

300mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

CURRENT ACCURACY

±8.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±3.0%

SETUP, RISE TIME

1500ms, 30ms / 230VAC          1500ms, 30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC      12ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE           Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY(Typ.)

83%

83%

83%

83%

AC CURRENT

0.4A/230VAC;0.8A/115VAC

INRUSH CURRENT(Typ.)

COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

 

OVER VOLTAGE

76 ~ 94V

55 ~ 68V

41 ~ 49V

27 ~ 35V

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ 70℃(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.2%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

SAFETY & EMC

(Note 5)

 

SAFETY STANDARDS

UL8750 (except for APC-25-350), CSA-C22.2 No. 250.0-13 (only for APC-25-700&1050), BIS IS15885, EAC TP TC 004,

IP42 approved; design refer to EN60950-1

WITHSTAND VOLTAGE

I/P-O/P:3KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020

 

OTHERS

MTBF

518.9K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

84*57*29.5(L*W*H)

PACKING

0.13Kg; 72pcs/10.4Kg/0.92CUFT

MODEL

APC-35-350

APC-35-500

APC-35-700

APC-35-1050

 

 

 

 

 

 

OUTPUT

RATED CURRENT

350mA

500mA

700mA

1050mA

DC VOLTAGE RANGE

28~100V

25~70V

15~50V

11~33V

RATED POWER

35W

35W

35W

34.7W

RIPPLE & NOISE (max.) Note.2

350mVp-p

350mVp-p

350mVp-p

350mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

CURRENT ACCURACY

±8.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±3.0%

SETUP, RISE TIME

1500ms, 40ms / 230VAC          1500ms, 40ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC      12ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE           Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY(Typ.)

84%

84%

84%

84%

AC CURRENT

0.5A/230VAC;0.75A/115VAC

INRUSH CURRENT(Typ.)

COLD START 45A(twidth=490μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

 

OVER VOLTAGE

110 ~ 130V

77 ~ 91V

55 ~ 65V

36 ~ 43V

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ 70℃(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.2%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

SAFETY & EMC

(Note 5)

 

SAFETY STANDARDS

UL8750 (only for APC-35-700&1050), CSA-C22.2 No. 250.0-13 (only for APC-35-1050), BIS IS15885, EAC TP TC 004,

IP42 approved; design refer to EN60950-1

WITHSTAND VOLTAGE

I/P-O/P:3KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020

 

OTHERS

MTBF

518.9K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

84*57*29.5(L*W*H)

PACKING

0.18Kg; 72pcs/14Kg/0.92CUFT

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  Derating may be needed under low input voltage. Please check the static characteristic for more details.

5.  The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.

7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

8.  For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Recently Viewed Items


People who bought this product, also bought