MEANWELL SP Series With PFC
Many In Stock
Ballast /Drivers
SP-75-48
S7
- Universal AC input / Full range
- Built in active PFC function, PF>0.95
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan
- High power density 18w/in3
- Low profile:43mm thickness
- Built-in remote ON-OFF control
- Built-in remote sense function
- Active AC surge current limiting
Specification:
MODEL |
SP-75-3.3 |
SP-75-5 |
SP-75-7.5 |
SP-75-12 |
SP-75-13.5 |
SP-75-15 |
SP-75-24 |
SP-75-27 |
SP-75-48 |
|
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
RATED CURRENT |
15A |
15A |
10A |
6.3A |
5.6A |
5A |
3.2A |
2.8A |
1.6A |
|
CURRENT RANGE |
0 ~ 15A |
0 ~ 15A |
0 ~ 10A |
0 ~ 6.3A |
0 ~ 5.6A |
0 ~ 5A |
0 ~ 3.2A |
0 ~ 2.8A |
0 ~ 1.6A |
|
RATED POWER |
49.5W |
75W |
75W |
75.6W |
75.6W |
75W |
76.8W |
75.6W |
76.8W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
VOLTAGE ADJ. RANGE |
3.14 ~ 3.63V |
4.75 ~ 5.5V |
7.13 ~ 8.25V |
11.4 ~ 13.2V |
12.8 ~ 14.9V |
14.3 ~ 16.5V |
22.8 ~ 26.4V |
25.7 ~ 29.7V |
45.6 ~ 52.8V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
SETUP, RISE TIME |
800ms, 60ms at full load |
|||||||||
HOLD UP TIME (Typ.) |
36ms at full load |
|||||||||
INPUT |
VOLTAGE RANGE Note.5 |
85 ~ 264VAC 120 ~ 370VDC |
||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||||
POWER FACTOR (Typ.) |
PF>0.93/230VAC 0.96/115VAC at full load |
|||||||||
EFFICIENCY (Typ.) |
70% |
76% |
79% |
81% |
82% |
82% |
83% |
83% |
83% |
|
AC CURRENT (Typ.) |
1.3A/115VAC 0.7A/230VAC |
|||||||||
INRUSH CURRENT (Typ.) |
COLD START 45A/230VAC |
|||||||||
LEAKAGE CURRENT |
<2mA / 240VAC |
|||||||||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||||||||
OVER VOLTAGE |
3.8 ~ 4.46V |
5.75 ~ 6.75V |
8.63 ~ 10.13V |
13.8 ~ 16.2V |
15.53 ~ 18.23V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
31.05 ~ 36.45V |
55.2 ~ 64.8V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||
FUNCTION |
REMOTE CONTROL(OPTION) |
CN3:4 ~ 10VDC POWER OFF, <0 ~ 0.8VDC POWER ON |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60℃ (Refer to output load derating curve) |
||||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||||
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
|||||||||
TEMP. COEFFICIENT |
±0.05%/℃ (0 ~ 50℃) |
|||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
||||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B,EN61000-3-2,-3 |
|||||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
|||||||||
OTHERS |
MTBF |
208.8K hrs min. MIL-HDBK-217F (25℃) |
||||||||
DIMENSION |
179*97*33mm (L*W*H) |
|||||||||
PACKING |
0.58Kg; 20pcs/12Kg/0.64CUFT |
MODEL |
SP-200-3.3 |
SP-200-5 |
SP-200-7.5 |
SP-200-12 |
SP-200-13.5 |
SP-200-15 |
SP-200-24 |
SP-200-27 |
SP-200-48 |
|
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
RATED CURRENT |
40A |
40A |
26.7A |
16.7A |
14.9A |
13.4A |
8.4A |
7.5A |
4.2A |
|
CURRENT RANGE |
0 ~ 40A |
0 ~ 40A |
0 ~ 26.7A |
0 ~ 16.7A |
0 ~ 14.9A |
0 ~ 13.4A |
0 ~ 8.4A |
0 ~ 7.5A |
0 ~ 4.2A |
|
RATED POWER |
132W |
200W |
200.2W |
200.4W |
201.1W |
201W |
201.6W |
202.5W |
201.6W |
|
RIPPLE & NOISE (max.) Note.2 |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
150mVp-p |
150mVp-p |
250mVp-p |
|
VOLTAGE ADJ. RANGE |
3.14 ~ 3.63V |
4.75 ~ 5.5V |
7.13 ~ 8.25V |
11.4 ~ 13.2V |
12.8 ~ 14.9V |
14.3 ~ 16.5V |
22.8 ~ 26.4V |
25.7 ~ 29.7V |
45.6 ~ 52.8V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
SETUP, RISE TIME |
600ms, 40ms at full load |
|||||||||
HOLD UP TIME (Typ.) |
20ms at full load |
|||||||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||||
POWER FACTOR (Typ.) |
PF>0.93/230VAC PF>0.97/115VAC at full load |
|||||||||
EFFICIENCY (Typ.) |
69% |
76% |
78.5% |
84% |
84% |
84% |
85% |
85% |
85% |
|
AC CURRENT (Typ.) |
3.5A/115VAC 1.7A/230VAC |
|||||||||
INRUSH CURRENT (Typ.) |
COLD START 50A/230VAC |
|||||||||
LEAKAGE CURRENT |
<2mA / 240VAC |
|||||||||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||||||||
OVER VOLTAGE |
3.63 ~ 4.46V |
5.5 ~ 6.75V |
8.25 ~ 10.13V |
13.2 ~ 16.2V |
14.85 ~ 18.2V |
16.5 ~ 20.25V |
26.4 ~ 32.4V |
29.7 ~ 36.45V |
52.8 ~ 64.8V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||||
FUNCTION |
REMOTE CONTROL(OPTION) |
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60℃ (Refer to output load derating curve) |
||||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||||
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
|||||||||
TEMP. COEFFICIENT |
±0.05%/℃ (0 ~ 50℃) |
|||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, CCC GB4943 approved |
||||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/70% RH |
|||||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B,EN61000-3-2,-3 |
|||||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
|||||||||
OTHERS |
MTBF |
183.8K hrs min. MIL-HDBK-217F (25℃) |
||||||||
DIMENSION |
199*99*50mm (L*W*H) |
|||||||||
PACKING |
0.85Kg; 20pcs/17.9Kg/1.28CUFT |
MODEL |
SP-240-5 |
SP-240-7.5 |
SP-240-12 |
SP-240-15 |
SP-240-24 |
SP-240-30 |
SP-240-48 |
|
OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
30V |
48V |
RATED CURRENT |
45A |
32A |
20A |
16A |
10A |
8A |
5A |
|
CURRENT RANGE |
0 ~ 45A |
0 ~ 32A |
0 ~ 20A |
0 ~ 16A |
0 ~ 10A |
0 ~ 8A |
0 ~ 5A |
|
RATED POWER |
225W |
240W |
240W |
240W |
240W |
240W |
240W |
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
4 ~ 6V |
6 ~ 9V |
10 ~ 14V |
12 ~ 18V |
20 ~ 28V |
27 ~ 33V |
41 ~ 56V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
SETUP, RISE TIME |
800ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load |
|||||||
HOLD UP TIME (Typ.) |
20ms/230VAC 20ms/115VAC at full load |
|||||||
INPUT |
VOLTAGE RANGE Note.5 |
88 ~ 264VAC 124 ~ 370VDC |
||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.98/115VAC at full load |
|||||||
EFFICIENCY (Typ.) |
79% |
83% |
86% |
86% |
87% |
88% |
89% |
|
AC CURRENT (Typ.) |
3.6A/115VAC 1.8A/230VAC |
|||||||
INRUSH CURRENT (Typ.) |
25A/115VAC 40A/230VAC |
|||||||
LEAKAGE CURRENT |
<2mA / 240VAC |
|||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||||||||
OVER VOLTAGE |
6.3 ~ 7.5V |
9.4 ~ 10.9V |
14.7 ~ 17.5V |
19 ~ 22.5V |
29.5 ~ 35V |
34.7 ~ 41V |
57.6 ~ 67.2V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||
FUNCTION |
FAN CONTROL |
RTH2≧40℃ FAN ON, ≦35℃ FAN OFF(Typ.) |
||||||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to output load derating curve) |
||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
|||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
|||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||
EMI CONDUCTION & RADIATION |
Compliance to EN55032 (CISPR32) Class B |
|||||||
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
|||||||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
|||||||
OTHERS |
MTBF |
284K hrs min. MIL-HDBK-217F (25℃) |
||||||
DIMENSION |
190*93*50mm (L*W*H) |
|||||||
PACKING |
0.8Kg; 18pcs/15.4Kg/1.04CUFT |
MODEL |
SP-320-3.3 |
SP-320-5 |
SP-320-7.5 |
SP-320-12 |
SP-320-13.5 |
SP-320-15 |
SP-320-24 |
SP-320-27 |
SP-320-36 |
SP-320-48 |
||
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
36V |
48V |
|
RATED CURRENT |
55A |
55A |
40A |
25A |
22A |
20A |
13A |
11.7A |
8.8A |
6.7A |
||
CURRENT RANGE |
0 ~ 60A |
0 ~ 55A |
0 ~ 40A |
0 ~ 25A |
0 ~ 22A |
0 ~ 20A |
0 ~ 13A |
0 ~ 11.7A |
0 ~ 8.8A |
0 ~ 6.7A |
||
RATED POWER |
181.5W |
275W |
300W |
300W |
297W |
300W |
312W |
315.9W |
316.8W |
321.6W |
||
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
220mVp-p |
240mVp-p |
||
VOLTAGE ADJ. RANGE |
3.14 ~ 3.63V |
4.5 ~ 5.5V |
6 ~ 9V |
10 ~ 13.2V |
12 ~ 15V |
13.5 ~ 18V |
20 ~ 26.4V |
26 ~ 31.5V |
32.4 ~ 39.6V |
41 ~ 56V |
||
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
||
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
±0.2% |
||
LOAD REGULATION |
±1.5% |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||
SETUP, RISE TIME |
800ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load |
|||||||||||
HOLD UP TIME (Typ.) |
16ms/230VAC 16ms/115VAC at full load |
|||||||||||
INPUT |
VOLTAGE RANGE Note.5 |
88 ~ 264VAC 124 ~ 370VDC |
||||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||||||
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.98/115VAC at full load |
|||||||||||
EFFICIENCY (Typ.) |
74% |
79% |
83% |
86% |
86% |
86% |
87% |
88% |
87% |
89% |
||
AC CURRENT (Typ.) |
115VAC |
2.5A |
5A |
|||||||||
230VAC |
1.5A |
2.5A |
||||||||||
INRUSH CURRENT (Typ.) |
20A/115VAC 40A/230VAC |
|||||||||||
LEAKAGE CURRENT |
<1mA / 240VAC |
|||||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
||||||||||||
OVER VOLTAGE |
3.8 ~ 4.5V |
5.75 ~ 6.75V |
9.4 ~ 10.9V |
13.8 ~ 16.2V |
15.5 ~ 18.2V |
18 ~ 21V |
27.6 ~ 32.4V |
33.7 ~ 39.2V |
45 ~ 52.5V |
57.6 ~ 67.2V |
||
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||||||||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +65℃ (Refer to "Derating Curve") |
||||||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
|||||||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
|||||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
||||||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 |
|||||||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A |
|||||||||||
OTHERS |
MTBF |
207K hrs min. MIL-HDBK-217F (25℃) |
||||||||||
DIMENSION |
215*115*50mm (L*W*H) |
|||||||||||
PACKING |
1.1Kg; 12pcs/14Kg/0.92CUFT |
MODEL |
SP-480-3.3 |
SP-480-5 |
SP-480-12 |
SP-480-15 |
SP-480-24 |
SP-480-48 |
|
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
12V |
15V |
24V |
48V |
RATED CURRENT |
85A |
85A |
40A |
32A |
20A |
10A |
|
CURRENT RANGE |
0 ~ 85A |
0 ~ 85A |
0 ~ 43A |
0 ~ 35A |
0 ~ 22A |
0 ~ 11A |
|
RATED POWER |
280.5W |
425W |
480W |
480W |
480W |
480W |
|
PEAK LOAD(10min.) Note.5 |
280.5W |
425W |
516W |
525W |
528W |
528W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
240mVp-p |
|
VOLTAGE ADJ. RANGE |
2.9 ~ 3.6V |
4.5 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 18V |
22 ~ 27.6V |
41~ 56V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±1.5% |
±1.5% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
SETUP, RISE TIME |
1000ms, 80ms/230VAC 2500ms, 80ms/115VAC at full load |
||||||
HOLD UP TIME (Typ.) |
18ms/230VAC 18ms/115VAC at full load |
||||||
INPUT |
VOLTAGE RANGE Note.6 |
85 ~ 264VAC 120 ~ 370VDC |
|||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.98/115VAC at full load |
||||||
EFFICIENCY (Typ.) |
74% |
79% |
85% |
85% |
88% |
89% |
|
AC CURRENT (Typ.) |
6.5A/115VAC 3.5A/230VAC |
||||||
INRUSH CURRENT (Typ.) |
20A/115VAC 40A/230VAC |
||||||
LEAKAGE CURRENT |
<2mA / 240VAC |
||||||
PROTECTION |
OVERLOAD |
87 ~ 103A |
87 ~ 103A |
45.15 ~ 58.05A |
36.75 ~ 47.25A |
23.1 ~ 29.7A |
11.55 ~ 14.85A |
Protection type : Constant current limiting, recovers automatically after conditions is removed |
|||||||
OVER VOLTAGE |
3.8 ~ 4.45V |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
18 ~ 21V |
28.8 ~ 33.6V |
57.6 ~ 67.2V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||
OVER TEMPERATURE Note.4 |
Shut down o/p voltage, recovers automatically after temperature goes down |
||||||
FUNCTION |
REMOTE CONTROL |
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off |
|||||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +60℃ (Refer to "Derating Curve") |
|||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
|||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:Short |
||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 |
||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), light industry level, criteria A |
||||||
OTHERS |
MTBF |
120.5K hrs min. MIL-HDBK-217F (25℃) |
|||||
DIMENSION |
278*127*43mm (L*W*H) |
||||||
PACKING |
1.7Kg; 6pcs/11.3Kg/0.67CUFT |
||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. TSW1: Detect on heatsink of power transistor. TSW2: Detect on heatsink of output diode. 5. 33% Duty cycle maximum within every 30 minute. Average output power should not exceed the rated power. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com} 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.