USAGE AREA

MEANWELL SE Series Single Output Power Supply

$ 25.10 $ 482.00

Many In Stock

Ballast /Drivers

SE-100-24

S7

Add to wishlist
Features :
  • AC input active surge current limiting
  • AC input range selected by switch
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Forced air cooling by built-in DC ball bearing fan
  • High power density 3w/inch3
  • With DC_OK signal output
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • UL / CUL approved
  • Low cost
MODEL SE-100-5 SE-200-15 SE-100-24/200-24/350-24 SE-200-27/350-27 SE-100-48
  DC VOLTAGE 5V 15V 24V 27V 48V
  RATED CURRENT 20A 14A 4.5A/8.8A/14.6A 7.8A/13A 2.3A/12.5A
  CURRENT RANGE 0 ~ 100A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 12.5A
  RATED POWER 100W 200W 100W/200W/350W 200W/350W 100W/600W
  RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
  VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 13.5 ~ 16.5V 22 ~ 26.4V 24 ~ 30V 43 ~ 56V
  VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
OUTPUT LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
  LOAD REGULATION ±2.0% ±0.5% ±0.5% ±0.5% ±0.5%
  SETUP, RISE TIME 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load
  HOLD UP TIME (Typ.) 20ms/230VAC 16ms/115VAC at full load
  VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 78% 83% 84% 87% 87% 87% 88%
AC CURRENT (Typ.) 12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.) 30A/115VAC 60A/230VAC
LEAKAGE CURRENT <2.0mA / 240VAC
    105 ~ 125% rated output power
  OVERLOAD Protection type : Shut down o/p voltage, re-power on to recover
    5.75 ~ 6.3V 13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 42 ~ 50V 57.6 ~ 67.2V
PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover
  OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
  WORKING TEMP. -20 ~ +60℃ (Refer to output load derating curve)
  WORKING HUMIDITY 20 ~ 90% RH non-condensing
  STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
  VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
  SAFETY STANDARDS UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only) approved
SAFETY & EMC WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
  ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
  MTBF 197K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 247*127*63.5mm (L*W*H)
  PACKING 1.2Kg; 6pcs/13.4Kg

 

MODEL

SE-450-3.3

SE-450-5

SE-450-12

SE-450-15

SE-450-24

SE-450-36

SE-450-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

3.3V

5V

12V

15V

24V

36V

48V

RATED CURRENT

75A

75A

37.5A

30A

18.8A

12.5A

9.4A

CURRENT RANGE

0 ~ 75A

0 ~ 75A

0 ~ 37.5A

0 ~ 30A

0 ~ 18.8A

0 ~ 12.5A

0 ~ 9.4A

RATED POWER

247.5W

375W

450W

450W

451.2W

450W

451.2W

RIPPLE & NOISE (max.) Note.2

200mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

2.97 ~ 3.63V

4.5 ~ 5.5V

10.8 ~ 13.5V

13.5 ~ 16.5V

21.6 ~ 28.5V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE Note.3

±3.0%

±3.0%

±1.0%

±1.0%

±1.5%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

LOAD REGULATION

±2.0%

±2.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC           1500ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC           12ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC selected by SW         254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

74%

78%

83%

84%

86%

86%

88%

AC CURRENT (Typ.)

10A/115VAC         6A/230VAC

INRUSH CURRENT (Typ.)

35A/115VAC          55A/230VAC

LEAKAGE CURRENT

<2.5mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 150% rated output power

Protection type : Shut down o/p voltage, re-power on to recovery

 

OVER VOLTAGE

3.8 ~ 4.6V

5.75 ~ 6.75V

13.8 ~ 16.2V

18 ~ 21V

32 ~ 36V

45 ~ 52V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recovery

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

ENVIRONMENT

WORKING TEMP.

-10 ~ +60℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃,10 ~ 95% RH

TEMP. COEFFICIENT

±0.05%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY

SAFETY STANDARDS

UL62368-1, EAC TP TC 004, BSMI CNS14336-1 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

 

OTHERS

MTBF

200K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

225*124*50mm (L*W*H)

PACKING

1.25Kg;12PCS/16Kg/1CUFT

 

MODEL

SE-600-5

SE-600-12

SE-600-15

SE-600-24

SE-600-27

SE-600-36

SE-600-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

27V

36V

48V

RATED CURRENT

100A

50A

40A

25A

22.2A

16.6A

12.5A

CURRENT RANGE

0 ~ 100A

0 ~ 50A

0 ~ 40A

0 ~ 25A

0 ~ 22.2A

0 ~ 16.6A

0 ~ 12.5A

RATED POWER

500W

600W

600W

600W

599.4W

597.6W

600W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

10 ~ 13.5V

13.5 ~ 16.5V

22 ~ 26.4V

24 ~ 30V

32 ~ 40V

43 ~ 56V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±2.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1000ms, 50ms/230VAC           1000ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           16ms/115VAC at full load

 

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC selected by switch          254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

78%

83%

84%

87%

87%

87%

88%

AC CURRENT (Typ.)

12A/115VAC         7.5A/230VAC

INRUSH CURRENT (Typ.)

30A/115VAC          60A/230VAC

LEAKAGE CURRENT

<2.0mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 125% rated output power

Protection type : Shut down o/p voltage, re-power on to recover

 

OVER VOLTAGE

5.75 ~ 6.3V

13.8 ~ 16.2V

18 ~ 21V

27.6 ~ 32.4V

31 ~ 36.5V

42 ~ 50V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +60℃ (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.05%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY & EMC

SAFETY STANDARDS

UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only) approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

 

OTHERS

MTBF

197K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

247*127*63.5mm (L*W*H)

PACKING

2.1Kg; 6pcs/13.4Kg/1.03CUFT

 

 

NOTE

1.   All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.   Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.   Tolerance : includes set up tolerance, line regulation and load regulation.

4.   The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

5.   This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions:

a} the end-devices is used within the European Union, and

b} the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c} the power supply is:

-  installed in end-devices with average or continuous input power greater than 75W, or

-  belong to part of a lighting system Exception:

Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 a} professional equipment with a total rated input power greater than 1000W;

b} symmetrically controlled heating elements with a rated power less than or equal to 200W

6.   Products made in Taiwan do not have KC logo. Please contact MEAN WELL sales for more information.

 

MODEL

SE-1000-5

SE-1000-9

SE-1000-12

SE-1000-15

SE-1000-24

SE-1000-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

9V

12V

15V

24V

48V

RATED CURRENT

150A

100A

83.3A

66.7A

41.7A

20.8A

CURRENT RANGE

0 ~ 150A

0 ~ 100A

0 ~ 83.3A

0 ~ 66.7A

0 ~ 41.7A

0 ~ 20.8A

RATED POWER

750W

900W

999.6W

1000.5W

1000.8W

998.4W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

3.3 ~ 5.5V

7.5 ~ 10V

10 ~ 13.5V

13.5 ~ 16.5V

22 ~ 27.5V

43 ~ 56V

VOLTAGE TOLERANCE Note.3

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC           1500ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           15ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC selected by TB2         254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

81%

84%

85%

86%

88%

89%

AC CURRENT (Typ.)

17.5A/115VAC         10A/230VAC

INRUSH CURRENT (Typ.)

35A/115VAC          55A/230VAC

LEAKAGE CURRENT

<2.5mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 125% rated output power

Protection type : Shut down o/p voltage, re-power on to recover

 

OVER VOLTAGE

5.75 ~ 6.75V

10.4 ~ 12.2V

13.8 ~ 16.2V

18 ~ 21V

28 ~ 32.4V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

 

OVER TEMPERATURE

70℃±5℃ (TSW1) detect on heatsink of power transistor

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

 

FUNCTION

DC_OK SIGNAL

PSU turn on:3.3V ~ 5.6V           PUS turn off:0 ~ 1V

REMOTE CONTROL

RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +60℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.05%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY

SAFETY STANDARDS

UL60950-1, BSMI CNS14336-1, EAC TP TC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

 

OTHERS

MTBF

251.6K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

278*127*63.5mm (L*W*H)

PACKING

2.5Kg; 6pcs/16Kg/1.38CUFT

MODEL

SE-1500-5

SE-1500-12

SE-1500-15

SE-1500-24

SE-1500-27

SE-1500-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

27V

48V

RATED CURRENT

300A

125A

100A

62.5A

55.6A

31.3A

CURRENT RANGE

0 ~ 300A

0 ~ 125A

0 ~ 100A

0 ~ 62.5A

0 ~ 55.6A

0 ~ 31.3A

RATED POWER

1500W

1500W

1500W

1500W

1501.2W

1502.4W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

3.3 ~ 5.5V

10.8 ~ 13.5V

13.5 ~ 16.5V

21.6 ~ 26.4V

25 ~ 30V

43.2 ~ 56V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±2.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

150ms, 12ms / 230VAC at full load

HOLD UP TIME (Typ.)

26ms / 230VAC at full load

 

 

 

INPUT

VOLTAGE RANGE

180 ~ 264VAC           254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

81%

85%

85%

87%

88%

89%

AC CURRENT (Typ.)

17.5A / 230VAC

INRUSH CURRENT (Typ.)

60A / 230VAC

LEAKAGE CURRENT

<3.5mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 125% rated output power

Protection type : Shut down o/p voltage, re-power on to recover

 

OVER VOLTAGE

5.75 ~ 6.75V

14.5 ~ 16.2V

18 ~ 21V

27.6 ~ 32.4V

31 ~ 35V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

 

FUNCTION

DC_OK SIGNAL

PSU turn on:3.3V ~ 5.6V           PUS turn off:0 ~ 1V

REMOTE CONTROL

RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.05%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY

SAFETY STANDARDS

UL62368-1, BSMI CNS14336-1, EAC TP TC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

 

OTHERS

MTBF

134.5K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

278*177.8*63.5mm (L*W*H)

PACKING

3.3Kg; 4pcs/14.2Kg/1.14CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.


QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question