USAGE AREA

MEANWELL PCD Series Constant Current Power Supply

$ 28.53 $ 48.00

Many In Stock

Ballast /Drivers

PCD-16-350B

S7

Add to wishlist
Features :
  • AC phase-cut dimming
  • Work with leading edge and trailing edge TRIAC dimmers
  • 115VAC or 230VAC models available
  • Built-in active PFC function
  • Constant current design
  • Protections: Short circuit / Over temperature
  • Cooling by free air convection
  • Fully isolated plastic case
  • IP42 design
  • Class Ⅱ power unit, no FG
  • Class 2 power unit
  • Suitable for LED related fixture or appliance(such as LED Decoration or Advertisement devices}
  • 100% full load burn-in test
  • Low cost
  • High reliability

PCD-16-350 [A]    A : With AC input 90~ 135VAC.

                            B : With AC input 180~ 295VAC

MODEL

PCD-16-350

PCD-16-700

PCD-16-1050

PCD-16-1400

 

 

 

OUTPUT

RATED CURRENT

350mA

700mA

1050mA

1400mA

OPERATING VOLTAGE RANGE

24 ~ 48V

16 ~ 24V

12 ~ 16V

8 ~ 12V

CURRENT ACCURACY

±5.0%

RATED POWER

16.8W

16.8W

16.8W

16.8W

RIPPLE & NOISE (max.) Note.1

4.6Vp-p

2.7Vp-p

2.2Vp-p

2Vp-p

NO LOAD OUTPUT VOLTAGE (max.)

60V

35V

25V

16V

SETUP TIME

500ms / 230VAC 2000ms / 115VAC at full load

 

 

 

 

INPUT

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

TOTAL HARMONIC DISTORTION

A series

THD< 20% when output loading≧70% at 115VAC

B series

THD< 20% when output loading≧70% at 230VAC input and output loading≧80% at 277VAC input

EFFICIENCY (Typ.)

82%

81%

80.5%

80%

AC CURRENT (Typ.)

0.4A/115VAC           0.2A/230VAC           0.15A/277VAC

INRUSH CURRENT(max.)

COLD START 10A(twidth=90μs measured at 50% Ipeak) at 115VAC / 230VAC

MAX. No. of PSUs on 16A CIRCUIT

BREAKER

A series

58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC

B series

128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.5mA / 120VAC / 240VAC

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +60℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

 

SAFETY & EMC

SAFETY STANDARDS

UL8750, CSA C22.2 No. 250.0-08(except for PCD-16-350), ENEC EN613471, EN61347-2-13, EN62384(for B type only),

BIS IS15885(for 350B,700B only), EAC TP TC 004, IP42 approved ; design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment (A type only), EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF

906.5K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

84*57*29.5mm (L*W*H)

PACKING

0.19Kg; 72pcs/14.7Kg/0.92CUFT

MODEL

PCD-25-350

PCD-25-700

PCD-25-1050

PCD-25-1400

 

 

 

 

OUTPUT

RATED CURRENT

350mA

700mA

1050mA

1400mA

OPERATING VOLTAGE RANGE

40 ~ 58V

24 ~ 36V

16 ~ 24V

12 ~ 18V

CURRENT ACCURACY

±5.0%

RATED POWER

20.3W

25.2W

25.2W

25.2W

RIPPLE & NOISE (max.) Note.1

4.6Vp-p

2.7Vp-p

2.2Vp-p

2Vp-p

NO LOAD OUTPUT VOLTAGE (max.)

60V

50V

35V

25V

SETUP TIME

500ms / 230VAC 2000ms / 115VAC at full load

 

 

 

 

 

 

INPUT

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

TOTAL HARMONIC DISTORTION

A series

THD< 20% when output loading≧70% at 115VAC

B series

THD< 20% when output loading≧70% at 230VAC input and output loading≧80% at 277VAC input

EFFICIENCY (Typ.)

82%

81%

80.5%

80%

AC CURRENT (Typ.)

0.6A/115VAC           0.3A/230VAC           0.2A/277VAC

INRUSH CURRENT(max.)

COLD START 10A(twidth=20μs measured at 50% Ipeak) at 115VAC / 230VAC

MAX. No. of PSUs

on 16A CIRCUIT BREAKER

A series

37 units (circuit breaker of type B) / 37 units (circuit breaker of type C) at 115VAC

B series

80 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.5mA 120VAC / 240VAC

 

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +60℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

 

 

SAFETY & EMC

 

SAFETY STANDARDS

UL8750, CSA C22.2 No. 250.0-08(except for PCD-25-350, PCD-25-700), ENEC EN613471, EN61347-2-13, EN62384(for B type only), BIS IS15885(for 350B,700B only), EAC TP TC 004,IP42 approved ; design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment (A type only), EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF

906.5K hrs min.       MIL-HDBK-217F (25℃)

DIMENSION

84*57*29.5mm (L*W*H)

PACKING

0.19Kg; 72pcs/14.7Kg/0.92CUFT

MODEL

PCD-40-350B

PCD-40-500B

PCD-40-700B

PCD-40-1050B

PCD-40-1400B

PCD-40-1750B

 

 

 

OUTPUT

RATED CURRENT

350mA

500mA

700mA

1050mA

1400mA

1750mA

OPERATING VOLTAGE RANGE

70 ~ 108V

45 ~ 80V

34 ~ 57V

22 ~ 38V

17 ~ 29V

13 ~ 23V

CURRENT ACCURACY

±5.0%

RATED POWER

37.8W

40W

39.9W

39.9W

40.6W

40.25W

RIPPLE & NOISE (max.) Note.1

9.5Vp-p

5.0Vp-p

3.1Vp-p

2.6Vp-p

2.5Vp-p

2.4Vp-p

NO LOAD OUTPUT VOLTAGE (max.)

118V

100V

63V

50V

35V

35V

SETUP TIME

500ms / 230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE

180~295VAC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

TOTAL HARMONIC DISTORTION

THD< 20% when output loading≧60%(PCD-40-350B loading≧65%)at 230VAC input and output loading≧75% at 277VAC input

EFFICIENCY (Typ.)

87%

87%

86%

86%

85%

85%

AC CURRENT (Typ.)

0.35A/230VAC 0.3A/277VAC

INRUSH CURRENT(Typ.)

COLD START 11A (twidth=50μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.5mA / 240VAC

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER TEMPERATURE

Shut down o/p voltage, auto-recovery

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +50℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

 

SAFETY & EMC

SAFETY STANDARDS

ENEC EN61347-1, EN61347-2-13 independent, EN62384, EAC TP TC 004,IP42 approved

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C ; EN61000-3-3,EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(Surge 2KV), criteria B,EAC TP TC 020

 

OTHERS

MTBF

362.331Khrs min.       MIL-HDBK-217F (25℃)

DIMENSION

128*60*31.5mm (L*W*H)

PACKING

0.23Kg;30pcs/7.9Kg/0.58CUFT

MODEL

PCD-60-500B

PCD-60-700B

PCD-60-1050B

PCD-60-1400B

PCD-60-1750B

PCD-60-2000B

PCD-60-2400B

 

 

 

 

OUTPUT

RATED CURRENT

500mA

700mA

1050mA

1400mA

1750mA

2000mA

2400mA

OPERATING VOLTAGE RANGE

70 ~ 108V

50 ~ 86V

34 ~ 57V

25 ~ 43V

20 ~ 34V

18 ~ 30V

15 ~ 25V

CURRENT ACCURACY

±5.0%

RATED POWER

54W

60.2W

59.85W

60.2W

59.5W

60W

60W

RIPPLE & NOISE (max.) Note.1

10.2Vp-p

5.6Vp-p

3.8Vp-p

3.4Vp-p

3.3Vp-p

2.4Vp-p

2.4Vp-p

NO LOAD OUTPUT VOLTAGE (max.)

118V

100V

63V

50V

50V

35V

35V

SETUP TIME

500ms / 230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE

180~295VAC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

TOTAL HARMONIC DISTORTION

THD< 20% when output loading≧60%(PCD-60-500B loading≧65%)at 230VAC input and output loading≧75% at 277VAC input

EFFICIENCY (Typ.)

87%

86%

86%

85%

85%

85%

84%

AC CURRENT (Typ.)

0.6A/230VAC        0.5A/277VAC

INRUSH CURRENT(Typ.)

COLD START 13A (twidth=50μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.5mA / 240VAC

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER TEMPERATURE

Shut down o/p voltage, auto-recovery

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +45℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

 

SAFETY & EMC

SAFETY STANDARDS

ENEC EN61347-1, EN61347-2-13 independent, EN62384, EAC TP TC 004,IP42 approved

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C ; EN61000-3-3,EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(Surge 2KV), criteria B,EAC TP TC 020

 

OTHERS

MTBF

358.030Khrs min.       MIL-HDBK-217F (25℃)

DIMENSION

128*60*31.5mm (L*W*H)

PACKING

0.35Kg;30pcs/11.5Kg/0.58CUFT

NOTE

1.  Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2.  Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.

3.  To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.

4.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

5.  For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Recently Viewed Items


People who bought this product, also bought