USAGE AREA

MEANWELL ODLC Series Constant Current Power Supply

$ 37.66 $ 44.00

Many In Stock

Ballast /Drivers

ODLC-45-350

S7

Add to wishlist

Features:

  • Constant Current mode output
  • Flicker free design
  • Plastic housing with class II design
  • Built-in active PFC function
  • No load power consumption<0.5W(Blank-Type}, Standby power consumption<0.5W(DA-Type}
  • IP67 rating for indoor or outdoor installations
  • Function options: 2 in 1 dimming (dim-to-off}; Auxiliary DC output; DALI

Applications:

  • LED panel lighting
  • LED flood lighting
  • Indoor LED lighting

Model Encoding:

ODLC-45[ ]-350 [ ]:

ODLC---->Series name

45---->Rated wattage 

A[ ]---->A:Auxiliary DC output(12V@50mA}

           [ ] None   

350--->Rated output current(350/500/700/1050/1400mA} 

[ ]---->Function options

Type

Function

Blank

2 in 1 dimming (0~10VDC and 10V PWM}

DA

DALI control technology


MODEL

ODLC-45 -350

ODLC-45 -500

ODLC-45 -700

ODLC-45 -1050

ODLC-45 -1400

 

 

 

 

 

 

OUTPUT

RATED CURRENT

350mA

500mA

700mA

1050mA

1400mA

RATED POWER

33.25W

45W

44.8W

45.15W

44.8W

CONSTANT CURRENT REGION Note.2

57 ~ 95V

54 ~ 90V

38 ~ 64V

26 ~ 43V

19 ~ 32V

OPEN CIRCUIT VOLTAGE(max.)

118V

115V

84V

63V

50V

CURRENT RIPPLE

5% max. @rated current

CURRENT TOLERANCE

±7.0%

SETUP TIME Note.4

500ms / 230VAC 1200ms/115VAC

AUXILIARY DC OUTPUT Note.5

Nominal 12V(deviation 11.4~12.6)@50mA for ODLC-45A only

 

 

 

 

 

 

 

 

 

INPUT

 

VOLTAGE RANGE Note.3

90 ~ 295VAC         127 ~ 417VDC

(Please refer to "STATIC CHARACTERISTIC" section)

FREQUENCY RANGE

47 ~ 63Hz

 

POWER FACTOR (Typ.)

PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

 

TOTAL HARMONIC DISTORTION

THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION” section)

EFFICIENCY (Typ.)

86%

85%

85%

84%

83%

AC CURRENT

0.6A/115VAC    0.4A/230VAC         0.3A/277VAC

INRUSH CURRENT (Typ.)

COLD START 30A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. No. of PSUs on 16A CIRCUIT BREAKER

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

NO LOAD/STANDBY POWER CONSUMPTION

No load power consumption<0.5W for Blank-Type,<1.2W for ODLC-45A Standby power consumption<0.5W for DA-Type

 

PROTECTION

 

SHORT CIRCUIT

Hiccup mode,auto-recovery after fault condition is removed for DA type; Hiccup mode,re-power on to recovery for other type

 

 

 

 

 

ENVIRONMENT

WORKING TEMP.

Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)

MAX. CASE TEMP.

Tcase=+85℃

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 40℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

 

 

SAFETY & EMC

SAFETY STANDARDS

UL8750(type”HL”),CSA C22.2 NO.250.13-12;ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14; BIS IS15885( for ODLC-45-700,1050,700DA,1050DA only), EAC TP TC 004,IP67 approved

DALI STANDARDS

Compliance to IEC62386-101, 102 for DA-Type only

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV),EAC TP TC 020

 

 

OTHERS

MTBF

408.8Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

111*77*28.5mm(L*W*H)

PACKING

0.42Kg; 24pcs/ 11Kg/ 0.72CUFT

MODEL

ODLC-65 -700

ODLC-65 -1050

ODLC-65 -1400

ODLC-65 -1750

 

 

 

 

 

 

OUTPUT

RATED CURRENT

700mA

1050mA

1400mA

1750mA

RATED POWER

65.1W

65.1W

64.4W

63W

CONSTANT CURRENT REGION Note.2

69 ~ 93V

46 ~ 62V

34 ~ 46V

27 ~ 36V

OPEN CIRCUIT VOLTAGE(max.)

118V

82V

60V

53V

CURRENT RIPPLE

5% max. @rated current

CURRENT TOLERANCE

±7.0%

SETUP TIME Note.4

500ms / 230VAC

AUXILIARY DC OUTPUT Note.5

Nominal 12V(deviation 11.4~12.6)@50mA for ODLC-65A only

 

 

 

 

 

 

 

 

 

INPUT

 

VOLTAGE RANGE Note.3

180 ~ 295VAC         254 ~ 417VDC

(Please refer to "STATIC CHARACTERISTIC" section)

FREQUENCY RANGE

47 ~ 63Hz

 

POWER FACTOR (Typ.)

PF>0.95/230VAC, PF>0.9/277VAC@full load

(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

 

TOTAL HARMONIC DISTORTION

THD< 20%(@load≧75%/230VAC,277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION” section)

EFFICIENCY (Typ.)

88%

86%

85%

85%

AC CURRENT

0.4A/230VAC         0.3A/277VAC

INRUSH CURRENT (Typ.)

COLD START 30A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410

MAX. No. of PSUs on 16A CIRCUIT BREAKER

 

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

NO LOAD / STANDBY POWER CONSUMPTION

No load power consumption <0.5W for Blank-Type, <1.2W for ODLC-65A Standby power consumption <0.5W for DA-Type

 

PROTECTION

 

SHORT CIRCUIT

Hiccup mode,auto-recovery after fault condition is removed for DA type; Hiccup mode,re-power on to recovery for other type

 

 

 

 

 

ENVIRONMENT

WORKING TEMP.

Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)

MAX. CASE TEMP.

Tcase=+85℃

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 45℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

 

 

SAFETY & EMC

 

SAFETY STANDARDS

UL8750(type”HL”);CSA C22.2 NO.250.13-12; ENEC EN61347-1 & EN61347-2-13 independent, EN62384, GB19510.1,GB19510.14; EAC TP TC 004, IP67 approved

DALI STANDARDS Note.7

Compliance to IEC62386-101,102 for DA-Type only

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Line:1KV),EAC TP TC 020

 

OTHERS

MTBF

380.7Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

121*77*28.5mm(L*W*H)

PACKING

0.43Kg; 24pcs/ 11.3Kg/ 0.74CUFT

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  Please refer to "DRIVING METHODS OF LED MODULE".

3.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

4.  Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time or set up failure

5.  Aux. 12V will be damaged with short circuit; It will not be available when output voltage is not in constant current region or output no load condition.

6.  The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

7. The DALI version driver does not support the bit 1: Lamp failure in the Command 144 Query status of the DALI standard.

8.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

9.  For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf