MEANWELL HDR Series Rail Mount Power Supply
Many In Stock
Ballast /Drivers
HDR-15-5
S7
Features:
- Ultra slim design with 70mm(4SU} width
- Universal input 85~264VAC(277VAC operational}
- No load power consumption<0.3W
- lsolation class Ⅱ
- Pass LPS (Limited power source) for Blank type
- DC output voltage adjustable
- Protections : Short circuit / Overload / Over voltage
- Cooling by free air convection (working temperature:-30~+70°C)
- DIN rail TS-35/7.5 or 15 mountable
- Over voltage category Ⅲ
- LED indicator for power on
Applications:
- Household control system
- Building automation
- lndustrial control system
- Factory automation
- Electro-mechanical apparatus
Model Encoding:
HDR - 100 - 12 N
HDR--------->Series name
100------>Rated wattage
12----->Output voltage
N------>Performance difference
Type |
Description |
Blank |
92W max, Pass LPS with a narrower output adjustable range |
N |
100W max, Non-LPS with a wider output adjustable range |
Specification:
MODEL |
HDR-15-5 |
HDR-15-12 |
HDR-15-15 |
HDR-15-24 |
HDR-15-48 |
|||
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
48V |
||
RATED CURRENT |
2.4A |
1.25A |
1A |
0.63A |
0.32A |
|||
CURRENT RANGE |
0 ~ 2.4A |
0 ~ 1.25A |
0 ~ 1A |
0 ~ 0.63A |
0 ~ 0.32A |
|||
RATED POWER |
12W |
15W |
15W |
15.2W |
15.4W |
|||
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
|||
VOLTAGE ADJ. RANGE |
4.5 ~ 5.5V |
10.8 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 29V |
43.2 ~ 55.2V |
|||
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
SETUP, RISE TIME |
2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load |
|||||||
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
|||||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) |
||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
EFFICIENCY (Typ.) |
80% |
85% |
85.5% |
86% |
87% |
|||
AC CURRENT (Typ.) |
0.5A/115VAC 0.25A/230VAC |
|||||||
INRUSH CURRENT (Typ.) |
COLD START 25A/115VAC 45A/230VAC |
|||||||
PROTECTION |
OVERLOAD |
110 ~ 145% rated output power |
||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||
OVER VOLTAGE |
5.75 ~ 6.75V |
14.2 ~ 16.2V |
18.8 ~ 22.5V |
30 ~ 36V |
56.5 ~ 64.8V |
|||
Protection type : Shut off o/p voltage, clamping by zener diode |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
|||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) RH non-condensing |
|||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||||||
OPERATING ALTITUDE |
2000 meters |
|||||||
OVER VOLTAGE CATEGORY |
Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters |
|||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN62368-1 |
||||||
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
|||||||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||
EMC EMISSION |
Parameter |
Standard |
Test Level / Note |
|||||
Conducted |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Radiated |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Harmonic Current |
EN61000-3-2 |
Class A |
||||||
Voltage Flicker |
EN61000-3-3 |
------- |
||||||
EMC IMMUNITY |
EN55024, EN55035, EN61000-6-2, EN61204-3 |
|||||||
Parameter |
Standard |
Test Level /Note |
||||||
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
||||||
Radiated Susceptibility |
EN61000-4-3 |
Level 3, criteria A |
||||||
EFT/Burest |
EN61000-4-4 |
Level 3, criteria A |
||||||
Surge |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
||||||
Conducted |
EN61000-4-6 |
Level 3, criteria A |
||||||
Magnetic Field |
EN61000-4-8 |
Level 4, criteria A |
||||||
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
||||||
OTHERS |
MTBF |
1166K hrs min. MIL-HDBK-217F (25℃) |
||||||
DIMENSION |
17.5*90*54.5mm (W*H*D) |
|||||||
PACKING |
78g;160pcs/13.5Kg/1.19CUFT |
MODEL |
HDR-30-5 |
HDR-30-12 |
HDR-30-15 |
HDR-30-24 |
HDR-30-48 |
|||
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
48V |
||
RATED CURRENT |
3A |
2A |
2A |
1.5A |
0.75A |
|||
CURRENT RANGE |
0 ~ 3A |
0 ~ 2A |
0 ~ 2A |
0 ~ 1.5A |
0 ~ 0.75A |
|||
RATED POWER |
15W |
24W |
30W |
36W |
36W |
|||
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
|||
VOLTAGE ADJ. RANGE |
4.5 ~ 5.5V |
10.8 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 29V |
43.2 ~ 55.2V |
|||
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
SETUP, RISE TIME |
500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load |
|||||||
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
|||||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) |
||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
EFFICIENCY (Typ.) |
82% |
88% |
89% |
89% |
90% |
|||
AC CURRENT (Typ.) |
0.88A/115VAC 0.48A/230VAC |
|||||||
INRUSH CURRENT (Typ.) |
COLD START 25A/115VAC 45A/230VAC |
|||||||
PROTECTION |
OVERLOAD |
105 ~ 160% rated output power |
||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||
OVER VOLTAGE |
5.75 ~ 7.5V |
15 ~ 18V |
18.8 ~ 22.5V |
30 ~ 36V |
57.6~ 67.2V |
|||
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
|||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) RH non-condensing |
|||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||||||
OPERATING ALTITUDE |
2000 meters |
|||||||
OVER VOLTAGE CATEGORY |
Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters |
|||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN62368-1 |
||||||
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
|||||||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||
EMC EMISSION |
Parameter |
Standard |
Test Level / Note |
|||||
Conducted |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Radiated |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Harmonic Current |
EN61000-3-2 |
Class A |
||||||
Voltage Flicker |
EN61000-3-3 |
------- |
||||||
EMC IMMUNITY |
EN55024, EN55035, EN61000-6-2, EN61204-3 |
|||||||
Parameter |
Standard |
Test Level /Note |
||||||
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
||||||
Radiated Susceptibility |
EN61000-4-3 |
Level 3, criteria A |
||||||
EFT/Burest |
EN61000-4-4 |
Level 3, criteria A |
||||||
Surge |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
||||||
Conducted |
EN61000-4-6 |
Level 3, criteria A |
||||||
Magnetic Field |
EN61000-4-8 |
Level 4, criteria A |
||||||
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
||||||
OTHERS |
MTBF |
968.1K hrs min. MIL-HDBK-217F (25℃) |
||||||
DIMENSION |
35*90*54.5mm (W*H*D) |
|||||||
PACKING |
0.12Kg;96pcs/12.5Kg/1.04CUFT |
MODEL |
HDR-60-5 |
HDR-60-12 |
HDR-60-15 |
HDR-60-24 |
HDR-60-48 |
|||
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
48V |
||
RATED CURRENT |
6.5A |
4.5A |
4A |
2.5A |
1.25A |
|||
CURRENT RANGE |
0 ~ 6.5A |
0 ~ 4.5A |
0 ~ 4A |
0 ~ 2.5A |
0 ~ 1.25A |
|||
RATED POWER |
32.5W |
54W |
60W |
60W |
60W |
|||
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
|||
VOLTAGE ADJ. RANGE |
5.0 ~ 5.5V |
10.8 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 29V |
43.2 ~ 55.2V |
|||
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||
SETUP, RISE TIME |
500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load |
|||||||
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
|||||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) |
||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
EFFICIENCY (Typ.) |
85% |
88% |
89% |
90% |
91% |
|||
AC CURRENT (Typ.) |
1.2A/115VAC 0.8A/230VAC |
|||||||
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
|||||||
PROTECTION |
OVERLOAD |
105 ~ 160% rated output power |
||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
||||||||
OVER VOLTAGE |
5.75 ~ 6.75V |
14.2 ~ 16.2V |
18.8 ~ 22.5V |
30 ~ 36V |
56.5 ~ 64.8V |
|||
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
|||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) RH non-condensing |
|||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||||||
OPERATING ALTITUDE |
2000 meters |
|||||||
OVER VOLTAGE CATEGORY |
Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters |
|||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN60950-1 |
||||||
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
|||||||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||
EMC EMISSION |
Parameter |
Standard |
Test Level / Note |
|||||
Conducted |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Radiated |
EN55032(CISPR32), CNS13438 |
Class B |
||||||
Harmonic Current |
EN61000-3-2 |
Class A |
||||||
Voltage Flicker |
EN61000-3-3 |
------- |
||||||
EMC IMMUNITY |
EN55024, EN55035, EN61000-6-2, EN61204-3 |
|||||||
Parameter |
Standard |
Test Level /Note |
||||||
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
||||||
Radiated Susceptibility |
EN61000-4-3 |
Level 3, criteria A |
||||||
EFT/Burest |
EN61000-4-4 |
Level 3, criteria A |
||||||
Surge |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
||||||
Conducted |
EN61000-4-6 |
Level 3, criteria A |
||||||
Magnetic Field |
EN61000-4-8 |
Level 4, criteria A |
||||||
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
||||||
OTHERS |
MTBF |
927.6K hrs min. MIL-HDBK-217F (25℃) |
||||||
DIMENSION |
52.5*90*54.5mm (W*H*D) |
|||||||
PACKING |
190g;60pcs/12.4Kg/0.97CUFT |
MODEL |
HDR-100-12 |
HDR-100-12N |
HDR-100-15 |
HDR-100-15N |
HDR-100-24 |
HDR-100-24N |
HDR-100-48 |
HDR-100-48N |
|||
OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
48V |
||||||
RATED CURRENT |
7.1A |
7.5A |
6.13A |
6.5A |
3.83A |
4.2A |
1.92A |
2.1A |
|||
CURRENT RANGE |
0 ~ 7.1A |
0 ~ 7.5A |
0 ~ 6.13A |
0 ~ 6.5A |
0 ~ 3.83A |
0 ~ 4.2A |
0 ~1.92A |
0 ~ 2.1A |
|||
RATED POWER |
85.2W |
90W |
92W |
97.5W |
92W |
100.8W |
92.2W |
100.8W |
|||
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
|||||||
VOLTAGE ADJ. RANGE |
Pass LPS |
12 ~ 13V |
15 ~ 17V |
24 ~ 25.5V |
48 ~ 48.7V |
||||||
Non LPS |
12~ 13.8V |
13.5 ~ 18V |
21.6 ~ 29V |
43.2 ~ 55.2V |
|||||||
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
|||||||
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||||||
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||||||
SETUP, RISE TIME |
500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load |
||||||||||
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
||||||||||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) |
|||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||||||
EFFICIENCY (Typ.) |
88% |
89% |
90% |
90% |
|||||||
AC CURRENT (Typ.) |
3A/115VAC 1.6A/230VAC |
||||||||||
INRUSH CURRENT (Typ.) |
COLD START 35A/115VAC 70A/230VAC |
||||||||||
PROTECTION |
OVERLOAD |
HDR-100 : 102 ~ 110% rated output power ; HDR-100-xxN : 105 ~ 150% rated output power |
|||||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
|||||||||||
OVER VOLTAGE |
14.2 ~ 16.2V |
18.8 ~ 22.5V |
30 ~ 36V |
56.5 ~ 64.8V |
|||||||
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
|||||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
||||||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) RH non-condensing |
||||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||||||||||
OPERATING ALTITUDE |
2000 meters |
||||||||||
OVER VOLTAGE CATEGORY |
Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters |
||||||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS |
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN60950-1 |
|||||||||
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
||||||||||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||||||
EMC EMISSION |
Parameter |
Standard |
Test Level / Note |
||||||||
Conducted |
EN55032(CISPR32), CNS13438 |
Class B |
|||||||||
Radiated |
EN55032(CISPR32), CNS13438 |
Class B |
|||||||||
Harmonic Current (Note 5) |
EN61000-3-2 |
Class A |
|||||||||
Voltage Flicker |
EN61000-3-3 |
------- |
|||||||||
EMC IMMUNITY |
EN55024, EN61000-6-2, EN61204-3 |
||||||||||
Parameter |
Standard |
Test Level /Note |
|||||||||
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
|||||||||
Radiated Susceptibility |
EN61000-4-3 |
Level 3, criteria A |
|||||||||
EFT/Burest |
EN61000-4-4 |
Level 3, criteria A |
|||||||||
Surge |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
|||||||||
Conducted |
EN61000-4-6 |
Level 3, criteria A |
|||||||||
Magnetic Field |
EN61000-4-8 |
Level 4, criteria A |
|||||||||
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
|||||||||
OTHERS |
MTBF |
856.5K hrs min. MIL-HDBK-217F (25℃) |
|||||||||
DIMENSION |
70*90*54.5mm (W*H*D) |
||||||||||
PACKING |
0.27Kg; 48pcs/14Kg/1.06CUFT |
||||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Harmonic current test at 90% load for HDR-100-xxN. 5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com} 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |