MEANWELL DRP Series Rail Mount Power Supply
Many In Stock
Ballast /Drivers
DRP-240-48
S7
- AC input range selectable by switch { this feature only for (480S)W }
- Built-in passive PFC function compliance to EN61000-3-2
- High efficiency 89% and low dissipation
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508(industrial control equipment}approved
- EN61000-6-2(EN50082-2} industrial immunity level
- 100% full load burn-in test
Specification:
MODEL |
DRP-240-24 |
DRP-240-48 |
|
OUTPUT |
DC VOLTAGE |
24V |
48V |
RATED CURRENT |
10A |
5A |
|
CURRENT RANGE |
0 ~ 10A |
0 ~ 5A |
|
RATED POWER |
240W |
240W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
24 ~ 28V |
48 ~ 53V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
800ms, 40ms/230VAC 800ms, 40ms/115VAC at full load |
||
HOLD UP TIME (Typ.) |
24ms/230VAC 24ms/115VAC at full load |
||
INPUT |
VOLTAGE RANGE Note.5 |
85 ~ 264VAC 120 ~ 370VDC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
POWER FACTOR (Typ.) |
0.96/230VAC 0.99/115VAC at full load |
||
EFFICIENCY (Typ.) |
84% |
85% |
|
AC CURRENT (Typ.) |
2.8A/115VAC 1.4A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 27A/115VAC 45A/230VAC |
||
LEAKAGE CURRENT |
<3.5mA / 240VAC |
||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
30 ~ 36V |
54 ~ 60V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
||
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +70℃ (Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||
EMC EMISSION |
Compliance to EN55011,EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 |
||
OTHERS |
MTBF |
289.9Khrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
125.5*125.2*100mm (W*H*D) |
||
PACKING |
1.2Kg; 12pcs/15.5Kg/1.29CUFT |
MODEL |
DRP-480-24 |
DRP-480-48 |
|
OUTPUT |
DC VOLTAGE |
24V |
48V |
RATED CURRENT |
20A |
10A |
|
CURRENT RANGE |
0 ~ 20A |
0 ~ 10A |
|
RATED POWER |
480W |
480W |
|
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
120mVp-p |
|
VOLTAGE ADJ. RANGE |
24 ~ 28V |
48 ~ 53V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
1200ms, 40ms/230VAC at full load |
||
HOLD UP TIME (Typ.) |
16ms/230VAC at full load |
||
INPUT |
VOLTAGE RANGE |
180 ~ 264VAC 250 ~ 370VDC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
POWER FACTOR (Typ.) |
≧0.7 |
||
EFFICIENCY (Typ.) |
89% |
||
AC CURRENT (Typ.) |
4A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 40A/230VAC |
||
LEAKAGE CURRENT |
<3.5mA / 240VAC |
||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
30 ~ 36V |
54 ~ 60V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
OVER TEMPERATURE |
100℃±5℃ (TSW : detect on heatsink of power switch) |
||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
|||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||
VIBRATION |
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 |
||
OTHERS |
MTBF |
180.9Khrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
227*125.2*100mm (W*H*D) |
||
PACKING |
2.4Kg; 6pcs/15Kg/1.75CUFT |
MODEL |
DRP-480S-24 |
DRP-480S-48 |
|
OUTPUT |
DC VOLTAGE |
24V |
48V |
RATED CURRENT |
20A |
10A |
|
CURRENT RANGE |
0 ~ 20A |
0 ~ 10A |
|
RATED POWER |
480W |
480W |
|
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
120mVp-p |
|
VOLTAGE ADJ. RANGE |
24 ~ 28V |
48 ~ 55V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
1200ms, 40ms/230VAC,115VAC at full load |
||
HOLD UP TIME (Typ.) |
23ms/230VAC,115VAC at full load |
||
INPUT |
VOLTAGE RANGE |
90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC |
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
POWER FACTOR (Typ.) |
≧0.7/230VAC only |
||
EFFICIENCY (Typ.) |
89% |
||
AC CURRENT (Typ.) |
8A/115VAC 3.2A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 27A/115VAC 45A/230VAC |
||
LEAKAGE CURRENT |
<3.5mA / 240VAC |
||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
30 ~ 36V |
59 ~66V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
OVER TEMPERATURE |
100℃±5℃ (TSW : detect on heatsink of power switch) |
||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
|||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||
VIBRATION |
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||
EMC EMISSION |
Compliance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020 |
||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 |
||
OTHERS |
MTBF |
187.9Khrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
227*125.2*100mm (W*H*D) |
||
PACKING |
2.6Kg; 6pcs / 16.6Kg / 1.75CUFT |
||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.