MEANWELL APV Series Constant Voltage Power Supply

$ 8.79 $ 30.00

Many In Stock

Ballast /Drivers

APV-8-12

S7

Add to wishlist

Features:

  • Constant voltage mode power supply
  • Universal AC input / Full range
  • Withstand 300VAC Surge input for 5 seconds
  • Protections: Short circuit / Over load / Over voltage
  • Fully isolated plastic case
  • Cooling by free air convection
  • Small and compact size
  • IP42 design
  • Class 2 power unit
  • Pass LPS
  • 100% full load burn-in test
  • Low cost, high reliability
  • Suitable for LED related fixture or appliance

SPECIFICATION

MODEL

APV-8-5

APV-8-12

APV-8-24

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

24V

RATED CURRENT

1.4A

0.67A

0.34A

CURRENT RANGE

0 ~ 1.4A

0 ~ 0.67A

0 ~ 0.34A

RATED POWER

7W

8.04W

8.16W

RIPPLE & NOISE (max.) Note.2

250mVp-p

250mVp-p

300mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME

500ms, 30ms / 230VAC           1500ms,30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC at full load

 

 

INPUT

VOLTAGE RANGE Note.4

90 ~ 264VAC         127 ~ 370VDC (Note.6)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

74%

80%

81%

AC CURRENT

0.15A/230VAC 0.3A/115VAC

INRUSH CURRENT(Typ.)

COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

 

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃(Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 45℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

SAFETY & EMC

SAFETY STANDARDS Note.8

UL8750,CSA C22.2 No.250.0-08,BIS IS15885(except for 5V), EAC TP TC 004 approved; design refer to EN60950-1,EN61347-1,EN61347-2-13

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020

 

OTHERS

MTBF

1631.5K hrs min.      MIL-HDBK-217F (25℃)

DIMENSION

60*30*23.5mm(L*W*H)

PACKING

0.05Kg;144pcs/7.6Kg/0.75CUFT

 

MODEL

APV-8E-5

APV-8E-12

APV-8E-24

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

24V

RATED CURRENT

1.4A

0.67A

0.34A

CURRENT RANGE

0 ~ 1.4A

0 ~ 0.67A

0 ~ 0.34A

RATED POWER

7W

8.04W

8.16W

RIPPLE & NOISE (max.) Note.2

250mVp-p

250mVp-p

300mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME

500ms, 30ms / 230VAC

HOLD UP TIME (Typ.)

20ms/230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE Note.4

180 ~ 264VAC         254 ~ 370VDC (Note.6)

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.5/230VAC at full load

EFFICIENCY (Typ.)

74%

77.5%

78.5%

AC CURRENT

0.15A/230VAC

INRUSH CURRENT(Typ.)

COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

 

 

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

 

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

MODEL

APV-12-5

APV-12-12

APV-12-15

APV-12-24

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

2A

1A

0.8A

0.5A

CURRENT RANGE

0 ~ 2A

0 ~ 1A

0 ~ 0.8A

0 ~ 0.5A

RATED POWER

10W

12W

12W

12W

RIPPLE & NOISE (max.) Note.2

100mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME           Note.6

1500ms, 30ms / 230VAC             1500ms,30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           15ms/115VAC at full load

 

 

INPUT

VOLTAGE RANGE            Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76%

82%

82%

84%

AC CURRENT

0.2A/230VAC 0.35A/115VAC

INRUSH CURRENT(Typ.)

COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

17.5 ~ 21V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

MODEL

APV-12E-5

APV-12E-12

APV-12E-15

APV-12E-24

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

2A

1A

0.8A

0.5A

CURRENT RANGE

0 ~ 2A

0 ~ 1A

0 ~ 0.8A

0 ~ 0.5A

RATED POWER

10W

12W

12W

12W

RIPPLE & NOISE (max.) Note.2

100mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME Note.6

500ms, 30ms / 230VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE Note.4

180 ~ 264VAC          254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.5/230VAC at full load

EFFICIENCY (Typ.)

75%

81%

81%

83%

AC CURRENT

0.2A/230VAC

INRUSH CURRENT(Typ.)

COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

 

17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

 

PROTECTION

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

17.5 ~ 21V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

MODEL

APV-16-5

APV-16-12

APV-16-15

APV-16-24

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

2.6A

1.25A

1A

0.67A

CURRENT RANGE

0 ~ 2.6A

0 ~ 1.25A

0 ~ 1A

0 ~ 0.67A

RATED POWER

13W

15W

15W

16.08W

RIPPLE & NOISE (max.) Note.2

100mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME           Note.6

1500ms, 30ms / 230VAC             1500ms,30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           12ms/115VAC at full load

 

 

INPUT

VOLTAGE RANGE            Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76%

80%

81%

83%

AC CURRENT

0.3A/230VAC 0.5A/115VAC

INRUSH CURRENT(Typ.)

COLD START 50A(twidth=185μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

13 units (circuit breaker of type B) / 22 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

17.5 ~ 21V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

MODEL

APV-16E-5

APV-16E-12

APV-16E-15

APV-16E-24

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

RATED CURRENT

2.6A

1.25A

1A

0.67A

CURRENT RANGE

0 ~ 2.6A

0 ~ 1.25A

0 ~ 1A

0 ~ 0.67A

RATED POWER

13W

15W

15W

16.08W

RIPPLE & NOISE (max.)Note.2

100mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME Note.6

500ms, 30ms / 230VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE Note.4

180 ~ 264VAC         254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.5/230VAC at full load

EFFICIENCY (Typ.)

75%

79%

80%

82%

AC CURRENT

0.3A/230VAC

INRUSH CURRENT(Typ.)

COLD START 50A(twidth=185μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

 

13 units (circuit breaker of type B) / 22 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

 

PROTECTION

 

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16V

17.5 ~ 21V

27.6 ~ 32.4V

Protection type : Shut off o/p voltage, clamping by zener diode

 

MODEL

APV-25-5

APV-25-12

APV-25-15

APV-25-24

APV-25-36

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

RATED CURRENT

3.5A

2.1A

1.68A

1.05A

0.7A

CURRENT RANGE

0 ~ 3.5A

0 ~ 2.1A

0 ~ 1.68A

0 ~ 1.05A

0 ~ 0.7A

RATED POWER

17.5W

25.2W

25.2W

25.2W

25.2W

RIPPLE & NOISE (max.) Note.2

120mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME           Note.6

1500ms, 30ms / 230VAC             1500ms,30ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           12ms/115VAC at full load

 

 

 

INPUT

VOLTAGE RANGE            Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

75.5%

82%

83%

83%

84%

AC CURRENT

0.4A/230VAC 0.8A/115VAC

INRUSH CURRENT(Typ.)

COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

 

PROTECTION

OVER LOAD

Above 105% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

OVER VOLTAGE

5.75 ~ 6.95V

13.8 ~ 16.2V

17.25 ~ 21V

27 ~ 32.4V

41.4 ~ 48.6V

Protection type : Shut down o/p voltage, re-power on to recover

 

MODEL

APV-35-5

APV-35-12

APV-35-15

APV-35-24

APV-35-36

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

RATED CURRENT

5A

3A

2.4A

1.5A

1A

CURRENT RANGE

0 ~ 5A

0 ~ 3A

0 ~ 2.4A

0 ~ 1.5A

0 ~ 1A

RATED POWER

25W

36W

36W

36W

36W

RIPPLE & NOISE (max.) Note.2

120mVp-p

150mVp-p

150mVp-p

180mVp-p

180mVp-p

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±2.0%

SETUP, RISE TIME           Note.6

1500ms, 40ms / 230VAC             1500ms,40ms / 115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC           12ms/115VAC at full load

 

 

INPUT

VOLTAGE RANGE            Note.4

90 ~ 264VAC           127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76.5%

83%

84%

84%

85%

AC CURRENT

0.5A/230VAC 0.75A/115VAC

INRUSH CURRENT(Typ.)

COLD START 45A(twidth=440μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

6 units (circuit breaker of type B) / 10 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

OVER LOAD

110%~160% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.95V

13.8 ~ 16.2V

17.25 ~ 21V

27 ~ 32.4V

41.4 ~ 48.6V

Protection type : Shut down o/p voltage, re-power on to recover

 

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  Derating may be needed under low input voltage. Please check the static characteristics for more details.

5.  The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6.  Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7.  The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.

8.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

9.  For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf