Skip to product information
1 of 3

S7

MEANWELL PLD Series Constant Current Power Supply

MEANWELL PLD Series Constant Current Power Supply

SKU SKU:PLD-25-350

Regular price $ 31.95 SGD
Regular price $ 34.50 SGD Sale price $ 31.95 SGD
Sale Sold out
Shipping calculated at checkout.
Power
Current
Type

Technical Details

Datasheet for PLD-25W

Datasheet for PLD-40W

Datasheet for PLD-60W

Features:

  • Universal AC input / Full range (up to 295VAC}
  • Built-in active PFC function
  • Constant current design
  • Protections: Short circuit / Over temperature
  • Cooling by free air convection
  • Fully isolated plastic case
  • Class 2 Power Unit
  • Class Ⅱ power unit, no FG
  • IP42 design
  • Suitable for LED related fixture or appliance(such as LED Decoration or Advertisement devices}
  • 100% full load burn-in test
  • Low cost
  • High reliability
  • Suitable for dry / damp locations

Specification:

 

MODEL

PLD-60-500B

PLD-60-700B

PLD-60-1050B

PLD-60-1400B

PLD-60-1750B

PLD-60-2000B

PLD-60-2400B

 

 

 

OUTPUT

RATED CURRENT

500mA

700mA

1050mA

1400mA

1750mA

2000mA

2400mA

OPERATING VOLTAGE RANGE

70 ~ 108V

50 ~ 86V

34 ~ 57V

25 ~ 43V

20 ~ 34V

18 ~ 30V

15 ~ 25V

CURRENT ACCURACY

±5.0%

RATED POWER

54W

60.2W

59.85W

60.2W

59.5W

60W

60W

RIPPLE & NOISE (max.) Note.1

10.2Vp-p

5.6Vp-p

3.8Vp-p

3.4Vp-p

3.3Vp-p

2.4Vp-p

2.4Vp-p

NO LOAD OUTPUT VOLTAGE (max.)

118V

100V

63V

50V

50V

35V

35V

SETUP TIME

500ms / 230VAC at full load

 

 

 

 

 

INPUT

VOLTAGE RANGE

180~295VAC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)

TOTAL HARMONIC DISTORTION

THD< 20% when output loading≧60%(PLD-60-500B loading≧65%)at 230VAC input and output loading≧75% at 277VAC input

EFFICIENCY (Typ.)

88%

87%

87%

86%

86%

86%

85%

AC CURRENT (Typ.)

0.6A/230VAC         0.5A/277VAC

INRUSH CURRENT(Typ.)

COLD START 25A (twidth=60μs measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

<0.5mA / 240VAC

PROTECTION

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER TEMPERATURE

Shut down o/p voltage, auto-recovery

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +45℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

 

SAFETY & EMC

SAFETY STANDARDS

ENEC EN61347-1, EN61347-2-13 independent, EN62384, BIS IS15885(for 700B,1050B,1400B only), EAC TP TC 004, IP42 approved

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C ; EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(Surge 2KV), criteria B, EAC TP TC 020

 

OTHERS

MTBF

458.852Khrs min.       MIL-HDBK-217F (25℃)

DIMENSION

128*60*31.5mm (L*W*H)

PACKING

0.34Kg;30pcs/11.2Kg/0.58CUFT

NOTE

1.  Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2.  Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.

3.  To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.

4.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

5.  For any application note and IP water proof function installation caution, please refer our user manual before using.

https://www.meanwell.com/Upload/PDF/LED_EN.pdf