Technical Details:

Datasheet.

Features:

  • Suitable for the redundant operation of 24V system
  • installed on DLN Rail TS35 / 5 or 15
  • Relay contact signal output and LED indicator for input failure alarm
  • Cooling by free air convection
  • 3 years warranty

SPECIFICATION

MODEL

DR-RDN20

 

 

OUTPUT

REVERSE VOLTAGE (max.)

30V

OUTPUT CURRENT (max.)

20A

VOLTAGE DROP

0.6V

LED INDICATORS

Two green LEDs indicating each input is "OK or fail"

 

INPUT

INPUT VOLTAGE RANGE

21 ~ 28V

NUMBER OF INPUTS

Two

INPUT CURRENT (max.)

20A per input

 

FUNCTION

INPUT VOLTAGE ALARM

When input is > 20V(±5%) or < 30V(±5%) relay contacts

RELAY CONTACT RATING (max.)

30VDC, 1A

 

 

ENVIRONMENT

WORKING TEMP.

-40 ~ +70℃

WORKING HUMIDITY

20 ~ 90% RH non condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mouning: Compliance to IEC60068-2-6

 

SAFETY & EMC

(Note 2)

SAFETY STANDARDS

UL508, EAC TP TC 004 approved

WITHSTAND VOLTAGE

Terminal-Chassis :0.5KVAC, Relay Contacts-Terminal :0.5KVAC

ISOLATION RESISTANCE

Terminal-Chassis :>100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF

996.8Khrs min.       MIL-HDBK-217F (25℃)

DIMENSION

55.5*125.2*100mm (W*H*D)

PACKING

0.5Kg; 20pcs/11Kg/1.29CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 24VDC input, rated load and 25℃ of ambient temperature.

2. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on    a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com}

3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.